Desenvolvimento do protótipo para apoiar o membro inferior durante o processo de antissepsia de fratura exposta

Katia Cilene Ayako Inomata,* Mildred Patricia Ferreira da Costa,** Silvia Cristina Fürbringer***
* MsC., Enfermeira, Centro Universitário São Camilo, 05025010, São Paulo, Brasil [katia.inomata@uol.com.br]. Morada para correspondência: Rua Raul Pompeia 144, 05025010, São Paulo, Brasil. Contribuição no artigo: pesquisa bibliográfica, escrita do artigo. ** Ph.D., Universidade de São Paulo. Professora, Universidade São Caetano do Sul, 01545080, São Paulo, Brasil [mildred@uol.com.br]. Contribuição no artigo: orientadora da pesquisa de mestrado. *** Ph.D., Universidade de São Paulo. Membro da Câmara técnica do Coren-SP. Professora, Universidade Monte Serrat, 01535001, São Paulo [silviafur@uol.com.br]. Contribuição no artigo: co-orientadora da pesquisa de mestrado, análise de dados e discussão

Recebido para publicação em: 18.05.16
Aceite para publicação em: 19.10.16

Referencia 2016 IV(11): 133-138

 

 

 

Cómo citar este documento

Inomata, Katia Cilene Ayako; Costa, Mildred Patricia Ferreira da; Fürbringer, Silvia Cristina. Desenvolvimento do protótipo para apoiar o membro inferior durante o processo de antissepsia de fratura exposta. Referencia 2016; IV(11). Disponible en <https://www.index-f.com/referencia/2016/411133.php> Consultado el

 

Resumo

Enquadramento: O aumento de pacientes com fratura exposta eleva o risco de infeção óssea. A infeção em sítio cirúrgico ortopédico constitui uma complicação grave. São utilizadas bandejas durante o procedimento de antissepsia da fratura exposta, passível de virar ou respingar na mesa cirúrgica e no chão, possibilitando a contaminação do campo cirúrgico e risco de queda do profissional no piso molhado. Objetivos: Desenvolver um protótipo para apoiar o membro inferior durante o processo de antissepsia da fratura exposta. Principais tópicos em análise: Projeto informacional. Foram levantadas informações para gerar soluções. No projeto conceitual foram construídos dois modelos de protótipos e testados em manequim, quanto à funcionalidade e design, permitindo apoio ao membro, irrigação sem respingos, destino adequado do líquido drenado e possibilitou a esterilização em autoclave. Na etapa projeto detalhado foi desenvolvido o desenho técnico e feito o registo da patente no Instituto Nacional da Propriedade Industrial. Conclusão: Após os testes, o modelo 1 apresentou vazamentos e não possibilitou a esterilização. O modelo 2 atendeu aos requisitos de funcionalidade e esterilização.
Palavras chave: Fraturas expostas/ Enfermagem/ Perioperatório/ Equipamento cirúrgico/ Osteomielite.
 

Resumen
Desarrollo de un prototipo para apoyar el miembro inferior durante la antisepsia de fractura abierta

Marco contextual: El aumento de los pacientes con fractura abierta acrecienta el riesgo de infección ósea. La infección en la cirugía ortopédica constituye una complicación grave. Durante la antisepsia de una fractura abierta se utilizan bandejas, que pueden girar o salpicar la mesa de operaciones y el suelo, lo que hace que el entorno quirúrgico se contamine y que el profesional corra el riesgo de resbalarse con el suelo mojado. Objetivos: Desarrollar un prototipo para apoyar el miembro inferior durante la antisepsia de una fractura abierta. Principales temas en análisis: Proyecto informativo en el que se recogió información para generar soluciones. En el diseño conceptual se construyeron y se probaron dos prototipos en un muñeco, y se observó que la funcionalidad y el diseño permiten apoyar el miembro, irrigar sin salpicar, gestionar de forma adecuada el líquido drenado y esterilizar en autoclave. En esta fase del proyecto detallado se desarrolló el diseño técnico y se registró la patente en el INPI Conclusión: Después de realizar las pruebas, el modelo 1 tuvo fugas y no permitió la esterilización. El modelo 2 fue adecuado respecto a los requisitos de funcionalidad y esterilización..
Palabras clave: Fracturas abiertas/ Enfermería perioperatoria/ Equipo quirúrgico/ Osteomielitis.
 

Abstract
Development of a prototype to support the lower limb during the antisepsis of open fractures

Background: The increase in the number of patients with open fractures increases the risk of bone infection. Orthopedic surgical site infections are severe complications. During the antisepsis of open fractures, trays can be turned over and spill on the surgical table and fall to the ground, increasing the risk of contamination of the surgical field and the professional's risk of falling in the wet floor. Objectives: To develop a prototype to support the lower limb during the antiseptic preparation of open fractures. Main topics under analysis: Informational design. Data were collected to create solutions. Two prototype models were produced in the conceptual design phase and their functionality and design were tested in manikins, providing support to the limb, allowing irrigation without splatter, adequate fluid draining and elimination, and autoclave sterilization. In the detailed design phase, the technical design was developed, and the patent was registered at the Brazilian National Institute of Industrial Property. Conclusion: After the tests, Model 1 showed leaks and did not enable sterilization. Model 2 met the functionality and sterilization requirements.
Key-words: Open fractures/ Perioperative nursing/ Surgical equipment/ Osteomyelitis.
 

Referências

Araújo, J. F. (2010). Estudo de propriedades mecânicas do polipropileno moldado por injeção em insertos de resinas. Curitiba, Brasil: Universidade Federal do Paraná.

Associação Brasileira de Normas Técnicas. (2012) Vestuário - referenciais de medidas do corpo humano. Rio de Janeiro, Brasil: ABNT.

Ercole, F. F., Chianca, T. C. M., Duarte, D., Starling, C. E. F., & Carneiro, M. (2011) Risco para infecção de sítio cirúrgico em pacientes submetidos a cirurgias ortopédicas. Revista latinoamericana de enfermagem, 19(6), 269-276.

Groover, M. P. (2012). Introdução aos processos de fabricação. Rio de Janeiro, Brasil: Ltc.

Goss, L. K. (2012). Staying up to date on disinfection and sterilization techniques: Brush up on AORN's recommendations for perioperative practice. Plastic Surgical Nursing, 32(3), 112-6.

Instituto Nacional da Propriedade Industrial. (2015). Busca de patentes. Recuperado de https://www.inpi.gov.br/pedidosem-etapas/faca-busca

McPherson, J. C., Runner, R. R., Shapiro, B. W., Walsh, D. S., Valle, J. S. & Buxton, T. B. (2008). An acute osteomyelitis model in traumatized rat tibiae involving sand as a foreign body, thermal injury, and microbial contamination. Comparative Medicine, 58(4), 369-374.

Rozenfeld, H., Forcellini, F. A., Amaral, D. C., Toledo, J. C., Silva, S. L., Alliprandini, D. H., & Scalice, R. K. (2006). Gestão de desenvolvimento de produtos. São Paulo, Brasil: Saraiva.

Sociedade Brasileira de Enfermeiros de Centro Cirúrgico, Recuperação Anestésica e Centro de Material e Esterilização. (2009). Práticas recomendadas (5ª.ed.). São Paulo, Brasil: SOBEC.

Villa, P. E., Nunes, T. R., Gonçalves, F. P., Martins, J. S., Lemos, G. S., & Moraes, F. B. (2013). Avaliação clínica de pacientes com osteomielite crônica após fraturas expostas tratados no Hospital de Urgências de Goiânia, Goiás. Revista Brasileira Ortopedica, 48(1), 22-28.

Principio de p�gina 

Pie Doc

 

RECURSOS CUIDEN

 

RECURSOS CIBERINDEX

 

FUNDACION INDEX

 

GRUPOS DE INVESTIGACION

 

CUIDEN
CUIDEN citación

REHIC Revistas incluidas
Como incluir documentos
Glosario de documentos periódicos
Glosario de documentos no periódicos
Certificar producción
 

 

Hemeroteca Cantárida
El Rincón del Investigador
Otras BDB
Campus FINDEX
Florence
Pro-AKADEMIA
Instrúye-T

 

¿Quiénes somos?
RICO Red de Centros Colaboradores
Convenios
Casa de Mágina
MINERVA Jóvenes investigadores
Publicaciones
Consultoría

 

INVESCOM Salud Comunitaria
LIC Laboratorio de Investigación Cualitativa
OEBE Observatorio de Enfermería Basada en la Evidencia
GED Investigación bibliométrica y documental
Grupo Aurora Mas de Investigación en Cuidados e Historia
FORESTOMA Living Lab Enfermería en Estomaterapia
CIBERE Consejo Iberoamericano de Editores de Revistas de Enfermería