ENTRAR            

 


 

 

 
Artículo de Investigación
 

 Ir a sumario    Acceso al texto completo

Avances en Enfermería
[av.enferm. -Col-]
2008 jul-dic; 26(2):35-42

 Manuscrito recibido: 29.01.08
Aceptado: 06.06.08

Un instrumento para evaluar la adherencia: su validez facial y confiabilidad

 

Astrid Contreras Orozco,* Inna Elida Flórez Torres,** Arleth Herrera Lián***


*Especialista en Enfermería médico-quirúrgica con énfasis en urgencias. Magíster en Enfermería con énfasis en cuidado para la salud cardiovascular. Profesora asociada, Facultad de Enfermería, Universidad de Sucre, Sincelejo, Colombia. astridco1704@yahoo.com. **Especialista en Enfermería médico-quirúrgica con énfasis en urgencias. Magíster en Enfermería con énfasis en cuidado para la salud cardiovascular. Profesora asistente, Facultad de Enfermería, Universidad de Cartagena, Cartagena, Colombia. iflorezt@unicartagena.edu.co ***Especialista en Enfermería médico-quirúrgica con énfasis en cuidados intensivos. Magíster en Enfermería con énfasis en cuidado para la salud cardiovascular. Profesora asociada, Facultad de Enfermería, Universidad de Cartagena, Cartagena, Colombia. aherreral@unicartagena.edu.co; arhely05@yahoo.es

Cómo citar este documento:
Contreras Orozco, Astrid; Elida Flórez, Inna; Herrera Lián, Arleth. Un instrumento para evaluar la adherencia: su validez facial y confiabilidad. Avances en Enfermería. 2008 jul-dic, 26(2). En: <http://www.index-f.com/rae/262/3542.php> Consultado el

 

Resumen

Se realizó una investigación metodológica que permitió determinar la validez facial y confiabilidad del instrumento para evaluar los factores que influyen en la adherencia a tratamientos farmacológicos y no farmacológicos en pacientes con factores de riesgo de enfermedad cardiovascular, con el fin de continuar su proceso de validación formal.
El instrumento fue diseñado por Bonilla y Gutiérrez, enfermeras docentes de la Universidad Nacional de Colombia; consta de 72 ítems, agrupados en cinco dimensiones con unacalificación Likert de tres puntos. Cuenta con validez facial y un índice de validez de contenido de 0,91.
Para determinar la segunda validez facial participaron 40 expertos y 40 pacientes, mediante tres criterios de calificación: claridad, precisión y comprensión; se encontró que 86% del total de los 72 ítems cumplieron los anteriores criterios. Como resultado se obtuvo una nueva versión del instrumento, de 62 ítems, y se concluye que este aparenta tener validez facial.
Para determinar la confiabilidad del instrumento, la segunda versión se aplicó a una muestra de 831 sujetos de las ciudades de Sincelejo y Cartagena durante los meses de septiembre y octubre de 2006, seleccionados mediante un muestreo aleatorio simple. La confiabilidad se evaluó a través de la consistencia interna, con un alfa de Cronbach de 0,797, y la estabilidad a través del coeficiente de correlación de Spearman, con un nivel de significancia de 0,01, el cual reportó ser estadísticamente significativo. Posteriores análisis del Alfa sugieren a los autores del instrumento la eliminación de algunos ítems para aumentar la confiabilidad.
Palabras clave: enfermedades cardiovasculares, confiabilidad y validez, evaluación, factores de riesgo.

Abstract
An instrument to evaluate adherence: its face validity and reliability

A methodological research was performed which allowed determining face validity and reliability of the instrument to evaluate the factors that influence on adherence to drug and non-drug treatments in patients with cardiovascular disease risk factors, with the objective of continuing their formal validation process.
The instrument was designed by Bonilla and Gutiérrez, professor nurses at National University of Colombia; it consists of 72 items, grouped in five dimensions with a Likert qualification of three points. It has face validity and a content validity index of 0,91.
To determine the second face validity, 40 experts and 40 patients participated through three qualification criteria: clarity, precision and comprehension, it was found that a 86% of the total of 72 items met the aforementioned criteria. As a result, a new version of the instrument was obtained, of 62 items, and the conclusion is that this new version appears to have more face validity.
To determine the reliability of the instrument, the second version was applied to a sample of 831 individuals of the cities of Sincelejo and Cartagena during the months of September and October 2006, selected through a simple random sampling. Reliability was evaluated through internal consistency, with a Cronbach alpha of 0,797, and stability through Spearman correlation coefficient, with a significance level of 0,01, which reported to be statistically significant. Later Alpha analyses suggest to the instrument authors the elimination of some items to increase reliability.
Key-words: Cardiovascular Diseases, Reproducibility of Results, Evaluation, Risk Factors.

Resumo
Um instrumento para avaliar a aderência: sua validade facial e confiabilidade

A pesquisa metodológica efetuada permitiu determinar a validade facial e confiabilidade do instrumento para avaliar os fatores que influem na aderência a tratamentos farmacológicos e não farmacológicos em pacientes com fatores de risco de doença cardiovascular, visando continuar com o processo de validação formal.
O instrumento foi delineado por Bonilla e Gutiérrez, enfermeiras docentes da Universidade Nacional da Colômbia; ele está composto de 72 itens, reunidos em cinco dimensões com uma qualificação Likert de três pontos. Ele conta com uma validade facial e um índice de validade de conteúdo de 0,91.
No intuito de determinar a segunda validade facial participaram 40 especialistas e 40 pacientes, mediante três critérios de qualificação: clareza, precisão e compreensão, encontramos que 86% do total dos 72 itens obedeceram alguns dos critérios anteriores. Com base nesse resultado, tiramos uma nova versão do instrumento, de 62 itens, e concluímos que ele parece ter validade facial.
Para determinar a confiabilidade do instrumento, a segunda versão foi aplicada a uma amostra de 831 indivíduos das cidades de Sincelejo e Cartagena durante os meses de setembro e outubro de 2006, escolhidos mediante uma amostra aleatória simples. A confiabilidade foi medida por meio da consistência interna, com um alfa de Cronbach de 0,797, e a estabilidade através do coeficiente de correlação de Spearman, com um nível de significância de 0,01, que resultou ser estadisticamente expressivo. Análises posteriores do Alfa sugerem a eliminação de alguns itens para aumentar a confiabilidade.
Palavras chave: Doenças Cardiovasculares, Reprodutibilidade dos Testes, Avaliação, Fatores de Risco.

Pie Doc

 

RECURSOS CUIDEN

 

RECURSOS CIBERINDEX

 

FUNDACION INDEX

 

GRUPOS DE INVESTIGACION

 

CUIDEN
CUIDEN citación

REHIC Revistas incluidas
Como incluir documentos
Glosario de documentos periódicos
Glosario de documentos no periódicos
Certificar producción
 

 

Hemeroteca Cantárida
El Rincón del Investigador
Otras BDB
Campus FINDEX
Florence
Pro-AKADEMIA
Instrúye-T

 

¿Quiénes somos?
RICO Red de Centros Colaboradores
Convenios
Casa de Mágina
MINERVA Jóvenes investigadores
Publicaciones
Consultoría

 

INVESCOM Salud Comunitaria
LIC Laboratorio de Investigación Cualitativa
OEBE Observatorio de Enfermería Basada en la Evidencia
GED Investigación bibliométrica y documental
Grupo Aurora Mas de Investigación en Cuidados e Historia
FORESTOMA Living Lab Enfermería en Estomaterapia
CIBERE Consejo Iberoamericano de Editores de Revistas de Enfermería