ENTRAR            

 


 

EVIDENTIA: ISSN 1697-638X

 

 

 

 

 

 

 

 

ORIGINALES

 

 Sumario

 

 

Troponina I, resultados obtenidos de catéteres venosos periféricos comparados con punción venosa directa

Francisco Ramos Cuenca, Auxiliadora Contín Oquiñena, Montserrat Rincón Cuenca, Alberto Oliver La Chica, Gemma Zorrilla Fernández, Isabel Catalán Francés
Unidad de Urgencias, Servicio de Críticos del Hospital Regional Universitario Carlos Haya. Málaga, España

Manuscrito recibido el 4.10.2011
Manuscrito aceptado el 6.1.2012

Evidentia 2012 abr-jun; 9(38)

 

 

 

Cómo citar este documento

Ramos Cuenca, Francisco; Contín Oquiñena, Auxiliadora; Rincón Cuenca, Montserrat; Oliver La Chica, Alberto; Zorrilla Fernández, Gemma; Catalán Francés, Isabel. Troponina I, resultados obtenidos de catéteres venosos periféricos comparados con punción venosa directa. Evidentia. 2012 abr-jun; 9(38). Disponible en: <https://www.index-f.com/evidentia/n38/ev7777.php> Consultado el

 

 

 

Resumen

Objetivo principal: Conocer la efectividad de un método de extracción de muestras sanguíneas para análisis de Troponina I, a través de un catéter venoso periférico. Metodología: Se incluyeron pacientes adultos a los que su médico solicitó analíticas de Troponina I y tenían canalizado un catéter venoso periférico, para infusión de sueros y/o perfusión de medicamentos. Una muestra se obtuvo del catéter venoso periférico a través de la llave de tres pasos, desechando 4 ml. antes de la extracción de sangre necesaria, simultáneamente se recogió otra muestra por punción venosa en el brazo contralateral, los resultados de las dos muestras se analizaron para comprobar la concordancia. Resultados principales: El coeficiente de correlación intraclase para las 73 pares de muestras de Troponina I ha sido de 0,997. Conclusión principal: Los resultados de Troponina I obtenidos, no muestran diferencias significativas.
Palabras clave: Cateterismo periférico/ Enfermería/ Flebotomía/ Miocardio/ Troponina I.

 

Abstract (Troponin I, results obtained by peripheral venous catheter compared with direct venipuncture)

 

Objective: This paper study the effectiveness drawing blood samples for troponin I analysis via peripheral venous catheters. Methods: The study included adult patients whose physician requested laboratory measurement of troponin I and who already had a peripheral venous catheter, used for perfusion of solutions and/or drugs. A blood sample was obtained from the peripheral venous catheter via the three-stage lock, discarding 4 milliliters prior to the collection of the required blood. At the same time another sample was obtained by venipuncture in the opposite arm. The two samples were analyzed to determine the concordance. Results: The correlation coefficient between the two extraction methods was 0.997. Conclusions: Troponin I obtained via peripheral venous catheters using the method described showed no significant differences as compared with samples obtained by direct venipuncture.
Key-words: Catheterization peripheral/ Phlebotomy/ Myocardium/ Nursing/ Troponin I.

 

Principio de p�gina 

Pie Doc

 

RECURSOS CUIDEN

 

RECURSOS CIBERINDEX

 

FUNDACION INDEX

 

GRUPOS DE INVESTIGACION

 

CUIDEN
CUIDEN citación

REHIC Revistas incluidas
Como incluir documentos
Glosario de documentos periódicos
Glosario de documentos no periódicos
Certificar producción
 

 

Hemeroteca Cantárida
El Rincón del Investigador
Otras BDB
Campus FINDEX
Florence
Pro-AKADEMIA
Instrúye-T

 

¿Quiénes somos?
RICO Red de Centros Colaboradores
Convenios
Casa de Mágina
MINERVA Jóvenes investigadores
Publicaciones
Consultoría

 

INVESCOM Salud Comunitaria
LIC Laboratorio de Investigación Cualitativa
OEBE Observatorio de Enfermería Basada en la Evidencia
GED Investigación bibliométrica y documental
Grupo Aurora Mas de Investigación en Cuidados e Historia
FORESTOMA Living Lab Enfermería en Estomaterapia
CIBERE Consejo Iberoamericano de Editores de Revistas de Enfermería