ENTRAR            

 


 

EVIDENTIA: ISSN 1697-638X

 

 

 

 

 

 

 

 

ORIGINALES

 

 Ir a Sumario

 

 

Prevalencia de efectos adversos relacionados con dispositivos intravasculares periféricos

Tomás Sebastián Viana,1 Fernando Núñez Crespo,2 José Miguel González Ruiz,3 Isabel Lema Lorenzo,3 Gema Martín Merino,4 Pablo Serrano Bazalote5
(1) Innovación y Desarrollo, Hospital Universitario de Fuenlabrada, Madrid, España. (2) Reanimación, Hospital Universitario de Fuenlabrada, Madrid, España. (3) Hospitalización médica, Hospital Universitario de Fuenlabrada, Madrid, España. (4) Hospitalización quirúrgica, Hospital Universitario de Fuenlabrada, Madrid, España. (5) Dirección médica, Hospital Universitario de Fuenlabrada, Madrid, España

Manuscrito recibido el 21.8.2009
Manuscrito aceptado el 3.12.2009

Evidentia 2010 ene-mar; 7(29)

 

 

 

Cómo citar este documento

Sebastián Viana, Tomás; Núñez Crespo, Fernando; González Ruiz, José Miguel; Lema Lorenzo, Isabel; Martín Merino, Gema; Serrano Bazalote, Pablo. Prevalencia de efectos adversos relacionados con dispositivos intravasculares periféricos. Evidentia. 2010 ene-mar; 7(29). Disponible en: <www.index-f.com/evidentia/n29/ev7155.php> Consultado el

 

 

 

Resumen

Objetivos: Conocer la prevalencia de efectos adversos (EA) relacionados con Dispositivos Intravenosos Periféricos (DIP), en adultos ingresados en un hospital y analizar la influencia de factores clave.
Métodos: Se rediseñó el registro clínico incluyendo factores relacionados con EA tras revisión bibliográfica. Se realizó un estudio en el segundo semestre de 2008 desde la información de la Historia clínica electrónica, seleccionando las variables: tamaño del catéter, lateralidad, lugar de colocación y alargadera con respecto a la aparición de los siguientes EA: flebitis, extravasación y obstrucción. Estos datos se analizaron con variables sociodemográficas del Conjunto Mínimo Básico de Datos (CMBD) realizando análisis bivariados.
Resultados: En los 4402 pacientes (55,8% hombres y 44,2% mujeres) la edad media fue de 59,3 años y la estancia media de 7,14 días. Las localización y calibre más frecuente fue antebrazo y número 20G (71,3%), el 20% tenían alargadera.
Se han encontrado <0,001 en los EA con en la variable sexo, calibre, colocación y tipo de paciente: médico o quirúrgico.
No fue significativo (p = 0,686) la relación entre EA, lateralidad y alargadera
Conclusiones: La aparición de EA se incrementa con la edad y estancia. El EA con mayor frecuencia es la extravasación, la flexura del codo es la localización con menos EA.
Palabras clave: Efectos adversos/ Flebitis/ Extravasación de Materiales terapéuticos/ Cateterismo venoso periférico.

 

Abstract (Adverse effects prevalence related to peripheral intravenous devices)

Purpose: The aim of this study is to determine adverse effects (EA) prevalence related to peripheral intravenous devices in hospital inpatients and to analyze the influence of key factors.
Method: A review of literature was performed to identify the adverse effects related to peripheral intravenous devices more frequently reported and those were included into the clinic report.
Data were obtained from the electronic clinic report during the second semester of 2008.
Variables of length and width of the catheter, side of insertion, sites of insertion and extension set were codified related to the EA phlebitis, extravasations and obstruction.
These data were analyzed with sociodemografic variables from the minimum basic group of data and bivariable analyzes were realized to find possible relations between the variables.
Results: 4402 patients were reviewed (55, 8% male and 44, 2 female) The median age was 59,3, with mean length of hospital stay of 7,14. The most common site of insertion of the catheter was forearm, 71,3% of the catheters were 20 gauge and 20% had adapters.
The comparison of the variables sex, gauge of the catheter, site of insertion and medical or surgery patient was p<0,001.
The comparison of EA with side of insertion and adapter has a p = 0,686 considered no statistically significant.
Conclusions: The frequency of EA related to peripheral intravenous devices is incrEAed with age and length of hospital stay.
The most common EA related to peripheral intravenous devices is the extravasations, the elbow flexure site of insertion has the lowest EA.
Key-words: Adverse Effects/ Phlebitis/ Extravasation of therapeutic Materials/ Catheterization, peripheral.

Principio de página 

Pie Doc

 

RECURSOS CUIDEN

 

RECURSOS CIBERINDEX

 

FUNDACION INDEX

 

GRUPOS DE INVESTIGACION

 

CUIDEN
CUIDEN citación

REHIC Revistas incluidas
Como incluir documentos
Glosario de documentos periódicos
Glosario de documentos no periódicos
Certificar producción
 

 

Hemeroteca Cantárida
El Rincón del Investigador
Otras BDB
Campus FINDEX
Florence
Pro-AKADEMIA
Instrúye-T

 

¿Quiénes somos?
RICO Red de Centros Colaboradores
Convenios
Casa de Mágina
MINERVA Jóvenes investigadores
Publicaciones
Consultoría

 

INVESCOM Salud Comunitaria
LIC Laboratorio de Investigación Cualitativa
OEBE Observatorio de Enfermería Basada en la Evidencia
GED Investigación bibliométrica y documental
Grupo Aurora Mas de Investigación en Cuidados e Historia
FORESTOMA Living Lab Enfermería en Estomaterapia
CIBERE Consejo Iberoamericano de Editores de Revistas de Enfermería